Leakage Current Detector


Loading...

___Part No.___
______
(勾選方式)
___Features___
___VCC(V)___
___Package___
___GF2140___
___Low Power 2-Wire Ground Fault Interrupter___
______
___* Directly powered from the AC line___
___* Build-in bridge rectifer___
___* Interface to SCR___
___* Adjustable trip current and time delay___
___* Minimum external components___
___* For two-wire system___
___* Be used in 110V or 220V system___
___6.5___
___Regulated___
___SOP-8___
___GF4141___
___LOW POWER GROUND FAULT___
___INTERRUPTER___
___* Powered from the AC line___
___* Low quiescent current___
___* Built-in diode rectifier___
___* Direct interface to SCR___
___* Precision sense amplifier___
___* Time delay___
___* For use with 110V or 220V systems___
___26___
___VREG___
___SOP-8___
___GF4146___
___GROUND FAULT INTERRUPTER___
______
___* For Two-Wire ALCI and RCD Applications___
___* Precision Sense Amplifier and Bandgap Reference___
___* Built-in AC Rectifier___
___* Direct DC Coupled to Sense Coil___
___* Low-Voltage SCR Disable___
___* Adjustable Sensitivity___
___* Built-in Noise Filter___
___* SCR Gate Driver___
___* Minimum External Components___
___* Ideal for 120V or 220V Systems___
___16___
___SOT-26___
___GF4147___
___GROUND FAULT___
___INTERRUPTER___
___* For GFCI and RCD Applications___
___* Built-in AC Rectifier___
___* Built-in Noise Filter___
___* Low-Voltage SCR Disable___
___* Direct DC Coupled to Sense Coil___
___* SCR Gate Driver___
___* Adjustable Sensitivity___
___* Low Quiescent Current___
___* Minimum External Components___
___* Ideal for 120V or 220V Systems___
___12.7___
___VREG___
___SOT-26___
___GF4149___
___GROUND FAULT___
___INTERRUPTER___
___* Precision Sense Amplifier and Bandgap Reference___
___* Low-VOS Offset___
___* Built-in Noise Filter___
___* High-Current SCR Gate Driver___
___* Adjustable Sensitivity___
___* Low Quiescent Current___
___* Minimum External Components___
___* Ideal for 120V or 220V Systems___
___14___
___VREG___
___SOT-26___
___M54133___
___Earth Leakage Current Detector( EIOH1&2 = ±20%)___
______
___* Improvement of ability against unwanted tripping by___
___lightning-surge and lightning impulse.___
___Two times counting system adopted.___
___* Improvement of ability against unwanted tripping by___
___inverter-noise.___
___Built-in operational amplifier (of low current dissipation) for active___
___low-pass filter.___
___Improved high-frequency, high harmonic superposition___
___performance___
___* Internal time delay function___
___* An external capacitor is used to set the delay time.___
___* High input sensitivity: VT=11.5mVrms Typ.___
___* Low-current dissipation (at RIREF=180kΩ)___
___In stand-by condition: IS=610μA Typ.___
___* High stabilities design___
___Adopt the circuits that is not affected by fluctuations of supply___
___voltage/ambient temperature.___
___7.0 ~ 12.0___
___SOP-16___
___M54133A___
___EARTH LEAKAGE CURRENT___
___DETECTOR___
___* Improvement of ability against unwanted tripping by___
___lightning-surge and lightning impulse.___
___Two times counting system adopted.___
___* Improvement of ability against unwanted tripping by___
___inverter-noise.___
___Built-in operational amplifier (of low current dissipation) for active___
___low-pass filter.___
___Improved high-frequency, high harmonic superposition___
___performance___
___* Internal time delay function___
___* An external capacitor is used to set the delay time.___
___* High input sensitivity: VT=11.5mVrms Typ.___
___* Low-current dissipation (at RIREF=180kΩ)___
___In stand-by condition: IS=610μA Typ.___
___* High stabilities design___
___Adopt the circuits that is not affected by fluctuations of supply___
___voltage/ambient temperature.___
___7.0 ~ 12.0___
___SOP-16___
___SOP-16N___
___M54134___
___Earth Leakage Current Detector( EIOH1&2 = ±10%)___
______
___* Improvement of ability against unwanted tripping by___
___lightning-surge and lightning impulse.___
___Two times counting system adopted.___
___* Improvement of ability against unwanted tripping by___
___inverter-noise.___
___Built-in operational amplifier (of low current dissipation) for active___
___low-pass filter.___
___Improved high-frequency, high harmonic superposition___
___performance___
___* Internal time delay function___
___* An external capacitor is used to set the delay time.___
___* High input sensitivity: VT=11.5mVrms Typ.___
___* Low-current dissipation (at RIREF=180kΩ)___
___In stand-by condition: IS=610μA Typ.___
___* High stabilities design___
___Adopt the circuits that is not affected by fluctuations of supply___
___voltage/ambient temperature.___
___7.0 ~ 12.0___
___SOP-16___
___SOP-16N___
___M54123L___
___Earth Leakage Current Detector___
______
___* With good input sensitivity current temperature characteristics___
___* High input sensitivity :VT=6.1mV (Typ.)___
___* Only need low external component count___
___* High noise and surge-proof___
___* Low power dissipation :PD=5mW (Typ.)___
___* May be used both as 100V and 200V.___
___* Wide temperature range : from -20 °C to +80°C___
___Vz=12.0V(Min)___
___DIP-8___
___SOP-8___
___SIP-8___
___M54123B___
___EARTH LEAKAGE CURRENT___
___DETECTOR___
______
___* With good input sensitivity current temperature characteristics___
___* High input sensitivity : VT=6.1mV (Typ.)___
___* Only need low external component count___
___* High noise and surge-proof___
___* Low power dissipation : PD=5mW (Typ.)___
___* May be used both as 100V and 200V.___
___* Wide temperature range : from -20°C to +80°C___
___Vz=12.0V(Min)___
___SOP-8___
___M54223___
___Earth Leakage Current Detector___
______
___* With good input sensitivity current temperature characteristics___
___* High input sensitivity :VT=6.1mV (Typ.)___
___* Only need low external component count___
___* High noise and surge-proof___
___* Low power dissipation :PD=5mW (Typ.)___
___* May be used both as 100V and 200V.___
___* Wide temperature range : from -20 °C to +80°C___
___Vs=12.0V(Min)___
___DIP-8___
___SOP-8___
___GM1851___
___Ground Fault Interrupter___
______
___* Internal power supply shunt regulator___
___* Externally programmable fault current threshold___
___* Externally programmable fault current integration time___
___* Direct interface to SCR___
___* Operates under line reversal; both load vs line and hot vs neutral___
___* Detects neutral line faults___
___VZ=26.0(Typ)___
___DIP-8___
___SOP-8___
___GV4145A___
___Low Power Ground Fault Interrupter___
______
___* No potentiomenter required___
___* Direct interface to SCR___
___* Supply voltage derived from AC line-26V shunt___
___* Adjustable sensitivity___
___* Grounded neutral fault detection___
___* 450μA quiescent current___
___* I deal for 120V or 220V systems___
___VZ=26.0(Typ)___
___DIP-8___
___SOP-8___
___M54147___
___CMOS LEAKAGE___
___PROTECTION CIRCUIT___
______
___* AC power supply___
___* Drive SCR, the output pulse width greater than 30ms___
___* Used to detect the A and AC signal___
___* Same higher accuracy for different leakage signal___
___* Excellent immunity to EMC___
___* 110V~220V(50~60Hz)___
___4.7~4.9___
___SOP-8___
___M54149___
___CMOS LEAKAGE___
___PROTECTION CIRCUIT___
______
___* AC power supply___
___* Drive SCR, the output pulse width greater than 30ms___
___* Used to detect the A and AC signal___
___* Same higher accuracy for different leakage signal___
___* Delay by external capacitor___
___* 110V~220V(50~60Hz)___
___* Width temperature range (TA=-30~+85°C)___
___* Available in SOP14 packages___
___4.65~4.95___
___SOP-14___
___GV4145A-Q___
___Low Power Ground Fault Interrupter___
______
___* No potentiomenter required___
___* Direct interface to SCR___
___* Supply voltage derived from AC line-26V shunt___
___* Adjustable sensitivity___
___* Grounded neutral fault detection___
___* 450μA quiescent current___
___* I deal for 120V or 220V systems___
___VZ=26.0(Typ)___
___SOP-8___
___MA2803___
___EARTH LEAKAGE DETECTOR___
______
___* Low Power Consumption: 5mW, 100V / 200V___
___* Built-in Voltage Regulator___
___* High-gain Differential Amplifier___
___* 0.4mA Output Current Pulse to Trigger SCRs___
___* Low External Part Count___
___* High Noise Immunity, Large Surge Margin___
___* Super Temperature Characteristic of Input Sensitivity___
___* Wide Operating Temperature Range: TA = −25°C to +80°C___
___* Operation from 12V to 20V Input___
___Vz=12.0V(Min)___
___SOP-8___